DJ100 100㎡ cold storage low temperature evaporator

DJ100 100㎡ cold storage evaporator Unit Cooler/ walk in cooler refrigeration unit is suitable to low temperature -35 degree.


  • Voltage: 3Phase,380v~460V,50/60Hz
  • Customize: 3Phase,220V/50/60Hz
  • Type: DJ100 100㎡ cold storage evaporator
  • Trading term: EXW, FOB, CIF DDP
  • Payment: T/T, Western Union, Money Gram, L/C
  • Certification : CE
  • Certification : 1 year
  • Product Detail

    Product Tags

    Company Profile

    2121

    Product Description

    2

    DJ100 100㎡ cold storage evaporator

    Ref.Capacity (kw)

    18.5

    Cooling Area (m²)

    100

    Qty

    4

    Diameter (mm)

    Φ500

    Air Volume (m3/h)

    4x6000

    Pressure (Pa)

    167

    Power (W)

    4x550

    Oil  (kw)

    10

    Catchment Tray (kw)

    2.2

    Voltage (V)

    220/380

    Installation Size (mm)

    3120*650*660

    Installation size data

    A(mm)

    B(mm)

    C(mm)

    D(mm)

    E(mm)

    E1(mm)

    E2(mm)

    E3(mm)

    F(mm)

    Inlet tube (φmm)

    Back trachea (φmm)

    Drain pipe

    3110

    690

    680

    460

    2830

    700

    700

    700

     

    19

    38

     
    1

    Maintenance work

    1. Leak detection of the evaporator is often carried out. Leakage is a common failure phenomenon of evaporators, and you should pay attention to frequent leak detection during use.

    When the ammonia evaporator leaks, it has a pungent odor, and there is no frost at the leaking point. Phenolphthalein test paper can be used to check the leak, because ammonia is alkaline, it turns red when it meets phenolphthalein test paper.When you look at it, it is usually a leak point where there is no frost in the evaporator. You can also use soapy water to find the leak at the leak.

    2. Check the frosting condition of the evaporator frequently. When the frost layer is too thick, it should be defrosted in time. When the frost is abnormal, it may be caused by blockage, and the cause should be found and eliminated in time.

    3. When the evaporator is out of service for a long time, it is advisable to bump the refrigerant into the accumulator or condenser and keep the pressure of the evaporator at about 0.05MPa (gauge pressure). If it is the evaporator in the salt pool, it needs to be flushed with tap water. After flushing, fill the pool with tap water.

    3